Viega offers the widest variety of pipe fitting solutions for securely connecting water, compressed air, fire sprinkler and more in carbon and stainless steel. Flameless and clean, the entire system can be pressed in seconds without manual tightening or without a complete system draining and/or shutdown. The entire Viega MegaPress system has our Smart Connect® technology to help easily identify unpressed connections.
Viega MegaPress
For use with Schedule 10 through Schedule 40 and Schedule 80
Benefits
- More than 200 configurations
- Approved for more applications than any other carbon steel press fitting system
- 50-90% installation cost savings compared to traditional methods
- First fitting approved for connecting gas pipe up to 4"
- Nearly 150 configurations from ½" to 4"
- More than 200 different fitting and valve configurations
-
Approved Applications
Water/Liquids
Chilled Water ≤50% Ethylene / Propylene glycol
Hydronic Heating Water ≤50% Ethylene / Propylene glycol
Isopropyl Alcohol
Fire Sprinkler NFPA 13, 13D, 13R
Steam Low-pressure
Steam ResidentialGases
Compressed Air Oil Concentration ≤25 mg/m
Nitrogen - N2
Carbon Dioxide - CO2 Dry
Argon - Ar
Oxygen - O2 Non-medical Keep free of oil and grease
Hydrogen - H2
Acetylene Test pressure 350 psi
Vacuum Minimum absolute pressure Maximum differential pressureFor additional information, please see the approved applications chart. View Viega Approved Applications
Viega MegaPressG
For use with Schedule 5 to Schedule 40 carbon steel pipe
Benefits
- HNBR sealing element approved for use in gas and fuel oil applications
- First fitting approved for connecting gas pipe up to 4"
- Nearly 150 configurations from ½" to 4"
- Approved for underground applications in accordance with code and local AHJ
-
Approved Applications
Fuels/Oils/Lubricants
Mineral Oil
Lube Oil Petroleum based
Propane
Butane
Natural Gas Primarily methane
Biodiesel ASTM D6751
Heating Fuel Oil
Diesel FuelGases
Compressed Air Oil Concentration ≤25 mg/m
Compressed Air Oil Concentration >25 mg/m
Nitrogen - N2
Carbon Dioxide - CO2 Dry
Argon - Ar
Hydrogen - H2
Acetylene Test pressure 350 psi
Vacuum Minimum absolute pressure Maximum differential pressureFor additional information, please see the approved applications chart. View Viega Approved Applications
Viega MegaPress FKM
For use with Schedule 5 to Schedule 40 carbon steel pipe
Benefits
- FKM sealing element allows for installation in higher temperature applications
- More than 180 configurations from ½" to 4"
- Approved for use in residential and low pressure steam, compressed air, fire protection and many fuel/oil applications
-
Approved Applications
Water/Liquids
Chilled Water ≤50% Ethylene / Propylene glycol
Hydronic Heating Water ≤50% Ethylene / Propylene glycol
Isopropyl Alcohol
Fire Sprinkler NFPA 13, 13D, 13R
Steam Low-pressure
Steam ResidentialFuels/Oils/Lubricants
Mineral Oil
Lube Oil Petroleum based
Biodiesel ASTM D6751
Heating Fuel Oil
Diesel Fuel
KeroseneGases
Compressed Air Oil Concentration ≤25 mg/m
Compressed Air Oil Concentration >25 mg/m
Nitrogen - N2
Carbon Dioxide - CO2 Dry
Argon - Ar
Hydrogen - H2
Acetylene Test pressure 350 psi
Vacuum Minimum absolute pressure Maximum differential pressureFor additional information, please see the approved applications chart. View Viega Approved Applications
Viega MegaPress Stainless
For use with 304 and 316 IPS stainless steel
Benefits
- Secure connections in less than 16 seconds
- Approved for use with Schedule 5 to Schedule 40 pipe
- MegaPress Stainless 316 comes with a choice of EPDM or FKM sealing elements
-
Approved Applications
Water/Liquids
Hot and Cold Potable Water Test pressure 600 psi
Rainwater / Graywater
Chilled Water ≤50% Ethylene / Propylene glycol
Hydronic Heating Water ≤50% Ethylene / Propylene glycol
Treated Water Fully desalinated, deionized, demineralized, distilled (open system)
Reverse Osmosis Water <1 MΩ
Paraffin Wax
Methyl Ethyl Ketone
Isopropyl Alcohol
Nitric Acid Concentration ≤10%
Phosphoric Acid Concentration ≤25%
Fire Sprinkler NFPA 13, 13D, 13R
Steam Low-pressure
Steam ResidentialFuels/Oils/Lubricants
Ethanol Pure grain alcohol
Mineral Oil
Lube Oil Petroleum based
Biodiesel ASTM D6751
Heating Fuel Oil
Diesel Fuel
KeroseneGases
Compressed Air Oil Concentration ≤25 mg/m
Compressed Air Oil Concentration >25 mg/m
Nitrogen - N2
Carbon Dioxide - CO2 Dry
Carbon Monoxide - CO
Argon - Ar
Ammonia Anhydrous
Oxygen - O2 Non-medical Keep free of oil and grease
Hydrogen - H2
Acetylene Test pressure 350 psi
Vacuum Minimum absolute pressure Maximum differential pressureSpecial Media
Methanol
Latex Paint
Urea Solution Concentration ≤40%
Caustic Soda Concentration ≤50%
Acetone Liquid
For additional information, please see the approved applications chart. View Viega Approved Applications
Need more information?
We're happy to send it over – just provide a few details so we can help.
Viega Fitting Systems
Innovative solutions. Tested to a higher standard.
Commercial and residential contractors worldwide trust Viega for all their plumbing and piping needs. With more applications and more approvals, Viega systems deliver unparalleled quality and durability. Learn more about how Viega pipe and fitting products can save you time and money on your next project.